Bacharach 3015-8005 H-10 PRO Universal Refrigerant Leak Detector with International Wall Plug Ultra-sensitive universal refrigerant leak detector Detects all CFC, HFC and HCFC refrigerants as low as 0.006 oz/yr, including R-410a and R-507 Dual power options allow battery operation for the best mobility or wall power for uninterrupted usage Visual and audible indicators include an incremental flashing LED in the probe tip, an internal speaker and a headphone jack Description The H-10 PRO is a highly responsive universal refrigerant leak detector using Bacharach’s tried-and-true heated diode sensor technology. It’s ultra-sensitive to all halogen-based, non-flammable CFC, HFC and HCFC refrigerants for reliable use in a wide range of refrigerant leak detection applications. The H-10 PRO has a long probe (4.5 ft.) for detecting leaks in hard-to-reach areas, visual and audible indicators to show relative leak sizes and an auto-zeroing feature (automatic mode only) for finding leaks in backgrounds where target gas is present. It has an internal sensor calibration reference to ensure optimum performance. Specifications Refrigerants Detected[1] All CFC, HFC and HCFC refrigerants, including but not limited to: R-12, R-22, R-134a, R-404A, R-410A, R-502, R-507, HFO-1233zd, HFO-1234yf and HFO-1234ze Sensitivity[2] 0.006 oz/yr (stationary) 0.1 oz/yr (moving per SAE J2791) Response Time 1 second Leak Indicators Visual (red LED in probe tip) and audible (via internal speaker or headphones) Automatic Background Adjustment Yes, in automatic mode Power 12 VDC internal rechargeable battery or via 100-240 VAC wall adapter/charger Run Time 3 hours (typical) on fully-charged battery Size (H x W x D) Unit: 8.3 x 10.5 x 5.4 in. (21.1 x 26.7 x 13.7 cm) Probe: 4.5 ft. (1.37 m) Weight 5.1 lbs. (2.3 kg) Sensor Life[3] 1 year (typical) Operating Conditions 32 to 104 °F (0 to 40 °C), 10 to 90% RH (non-condensing), 1 ATM Warm-up Time 2 minutes (approximate) Approvals CE mark Warranty Instrument - 3 Years Sensor, Battery - 1 Year Does not include probe, filters or leak bottle [1] DO NOT use this device to detect for leaks of refrigerants which are rated as combustible/flammable gases (e.g. ASHRAE A2- or A3- rated refrigerants). [2] Sensitivity for R-12, R-22, R-124a, R-410A, R-404A and R-507 when unit is set to small leak setting, manual mode. [3] Based on normal use. Consistent and/or constant exposure to high levels of refrigerant will deteriorate the sensor life more quickly. Increasing the sensor heater will also impact sensor life
read more