Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in System Flushing - Mastercool
Mar 23, 2020 at 03:11 pm —
MASTERCOOL 69900-220 (220-240 V / 50/60 HZ) “MASTERCLEANSE” FLUSH MACHINE

MASTERCOOL 69900-220 (220-240 V / 50/60 HZ) “MASTERCLEANSE” FLUSH MACHINE

INTRODUCTION OF MASTERCOOL 69900-220 (220-240 V / 50/60 HZ) “MASTERCLEANSE” FLUSH MACHINE FOR COMPLETE PERFECT FLUSHING OF AIR-COND AND REFRIGERATION SYSTEMS MASTERCOOL 69900-220 (220-240 V / 50/60 HZ) “MASTERCLEANSE” FLUSH MACHINE = RM4,200.00 PER UNIT (1-7-2025=AAA30.265) (2-9-2021=AA31.40) OPTIONAL PART NEED TO BUY   MASTERCOOL 91092-A Flush Gun (Flush Gun Assembly W/Rubber Tip) = RM106.00 PER PC * NEED 2PCS (1-7-2025=AAA30.528) (2-9-2021=AA30.65) * Price no longer valid, wait for new shipment!   SOLVENT MASTERCOOL 91049-32 OF 32 OZ (0.907185 KG) BOTTLE OF FLUSH SOLVENT (MADE IN USA) MASTERCOOL 91049-128 1 GALLON (3.78L) BOTTLE OF FLUSH SOLVENT (MADE IN USA) = RM225.00 PER BOTTLE (1-7-2025=AAA30.316) (2-9-2021=AA30.45) * Keep stock!  MASTERCOOL 91049-128-4 OF 4 PACKS OF 1 GALLON (3.78L) BOTTLE OF FLUSH SOLVENT (MADE IN USA) * Keep stock! Note A)  Add clean Mastercool flushing fluid to flushing machine tank by removing the flush fill cap 2 . A minimum of 1 gallon (3.78L) of flushing fluid recommended. B)  The Max pressure rating for the 69900-13 fitting is 113psi.  How To Flush AC System After Compressor Failure? https://carfromjapan.com/article/car-maintenance/how-to-flush-ac-system-after-compressor-failure/ PURGING PROCEDURE   If a purge selection valve is available: 1. Turn the purge selection valve to the preferred purge source. a. To use an external purge gas source (Nitrogen is preferred. If air is used, the air source must be clean and dry.), attach the gas source to external “PURGE GAS CONNECTION” 11 . The pressure of the external gas cannot exceed 90 PSI (6.2 Bar). • Turn the purge selection valve 10 to “EXTERNAL AIR/N2”. b. To use the internal nitrogen source, screw a bottle of nitrogen onto the regulator. • Turn the selector valve 10 to “INTERNAL N2”. 2. Turn the “FLUSH” valve 8 to a horizontal position as in “Valve Position 2”. 3. Check that all connections are tight. 4. When ready to purge turn the “PURGE” valve 9 to “OPEN”. 5. Continue purging until all of the flush fluid is out of the system and the system is dry. Product Description Mastercool introduces its new “MASTERCLEANSE” large volume flush machines designed to flush all HVAC/R and automotive systems. “MASTERCLEANSE” will be commonly used for removal of all solids and residues caused by breakage of compressor or filters. Designed with durable roll-away wheels and handle, this machine can conveniently move as needed.    FEATURES:   Stainless steel ball valve controls 1/4” SAE connection Additional external container connection External nitrogen bottle connection Pump equipped with mechanical seal and PTFE gasket Mechanical filter present at suction side SPECIFICATIONS:   Pump Flow Rate: 4 g/min (16 l/min) Pump Motor: 300 watts Pump Horsepower: 110V/60 Hz – 0.4 HP or 220-240V/50/60 Hz – 0.28 HP Full Load Amperage: 110V/60 Hz – 2.4 amps or 220-240V/50/60 Hz – 1.7 amps Flush Container: 2.6 gal (10 l) Hoses: 9 ft (3 m) flexible, clear coiled Dimensions: 15” (l) x 16” (w) x 24” (h) /with handle extended 36” (h) (381 mm (l) x 406 mm (w) x 609 mm (h) /with handle extended 914 mm (h)) Weight: 42 lbs (19 kg) Application Yes, the system is suitable for large VRF systems. Probably more so than automotive. The unit will push the flush agent through a system that has a return route. You can continually fill the reservoir until the system is fully flooded with flush. The unit will have a push pressure from the pump but it is not intended to pressurise the system. The system needs to be an open circuit. 30 meters pipe length is easily handled. It is recommended that nitrogen be used to clear the system of residual flush agent when flushing is complete. We do not recommend flushing a complete system. It is best to flush the individual components. As far as the length of tubing that can be flushed, as long as there is flow through the tubing, there is no restriction on the tube length. It is up to the technician to determine how long to do the flushing. If the flow is lower due to the length of the tubing, the flushing time will be longer. These figures should work for the 69900 as well as it appears to be based on the volume of the pipe interior. With the 69900, the reservoir is 10lt capacity, however, it is not pressurised. It is possible to add more flush fluid as required while it is pumping. As much as is required with no real upper limit.  If more than 10lt is required, it will be necessary to have a container to receive the excess fluid when clearing the lines on completion of the job. 1. The solvent will mix with any oil in the system being flushed. It can not be separated from the oil once mixed.  2. The colour of the flush fluid will determine when the flush fluid should be replaced. It is possible to use a refractometer to determine exactly when the fluid should be changed. It will be trial and error to determine the best levels for when to change.  3. The filter is a particulate filter and can be cleaned for re-use. If damaged, the filter screen can be replaced. P/N 69900-FS   SPARE PART: 1)MASTERCOOL CM36 MOTOR 3.7 BAR, 10L/MIN (C/W 6.3UF CAP.) FOR 69900-220 (1PH/50/60 HZ) FLUSH MACHINE   read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Temperature Display / Controller - BELIMO
Mar 23, 2020 at 01:02 pm —
BELIMO T24A1T MECHANICAL HEATING/COOLING THERMOSTAT (0° TO 40°C) (AC24V 50/60 HZ)

BELIMO T24A1T MECHANICAL HEATING/COOLING THERMOSTAT (0° TO 40°C) (AC24V 50/60 HZ)

BELIMO T24A1T MECHANICAL HEATING/COOLING THERMOSTAT (0° TO 40°C) (AC24V 50/60 HZ) = PHASED OUT Note 24A1T phased out, doesn't have direct replacement model. EXT-T24-D201 is similar thermostat model with display) • For control of heating or cooling in zone control systems • 0...10 VDC, 1 mA or 3-point 24VAC, 1A • Setpoint 0...40 °C • P or PI mode selection • Occupancy mode control • Change-over function • External sensor TG-K340B (Optional) • Auto change-over sensor TG-A130B (Optional) Sensor The controller has a built-in temperature sensor element. External sensor TG-K340B can be connected. See function selection for jumper setting.   For auto change-over function, sensor TG-A130B should be used. Note For AHU, if your application is 2-10V can go for:   1) T24A1T (no display) 2) EXT-T24-D201 (with display)   it is depend on your application and customer requirement Phased Out T24A1T phased out, doesn't have direct replacement model.  EXT-T24-D201 is similar thermostat model with display. read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Parts, Components and Accessories - Carrier
Mar 17, 2020 at 10:54 am —
CARRIER (TORIN) LA01EA750-25 (FOR HAT395 MOTOR) PROPELLER FAN (29.5IN)- (38LZA150)

CARRIER (TORIN) LA01EA750-25 (FOR HAT395 MOTOR) PROPELLER FAN (29.5IN)- (38LZA150)

CARRIER (TORIN) LA01EA750-25 (FOR HAT395 MOTOR) PROPELLER FAN (29.5IN)- (38LZA150)   read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Air-Cond and Refrigeration Tooling - DAIKIN
Mar 16, 2020 at 06:47 pm —
DAIKIN D2265586 ASSY AIR SWING MULTI (PANEL) FOR CEILING CASSETTE FAN COIL UNIT

DAIKIN D2265586 ASSY AIR SWING MULTI (PANEL) FOR CEILING CASSETTE FAN COIL UNIT

DAIKIN D2265586 ASSY AIR SWING MULTI (PANEL) FOR CEILING CASSETTE FAN COIL UNIT   read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Lubricant Oil and Equipment - SUNISO Belgium
Mar 16, 2020 at 04:49 pm —
BELGIUM REFRIGERATION OIL (MINERAL)

BELGIUM REFRIGERATION OIL (MINERAL)

BELGIUM REFRIGERATION OIL (MINERAL) Type and Packing 3GS X 1 GALLON (3.78 LITRE) SUNISO REFRIGERATION OIL (BELGIUM) 4GS X 1 GALLON (3.78 LITRE) SUNISO REFRIGERATION OIL (BELGIUM) 5GS X 1 GALLON (3.78 LITRE) SUNISO REFRIGERATION OIL (BELGIUM) 5GS X 4 LITRE SUNISO REFRIGERATION OIL (BEIGIUM) (6-CAN/BOX)     read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added a news
Mar 14, 2020 at 09:25 pm —
EAKON ACADEMY GRADUATION CEREMONY HELD AT HOTEL SRI PETALING K.L ON 12-3-2020

EAKON ACADEMY GRADUATION CEREMONY HELD AT HOTEL SRI PETALING K.L ON 12-3-2020

EAKON ACADEMY GRADUATION CEREMONY HELD AT HOTEL SRI PETALING K.L ON 12-3-2020   EAKON ACADEMY VOCATIONL SKILLS TRAINING under leadership of Dato’ Sri Dr. Ricky Yaw organized a first ever Graduation Ceremony for the 26 of graduates under Sijil Kemahiran Malaysia (SKM) Level 2 & 3 and Sijil Kecekapan Kemahiran (SKK) courses which was held on 12 March 2020 at Hotel Sri Petaling, Kuala Lumpur and was opened by Mr. Dolkipli Bin Saian (Ketua Pegawai Operasi ABM Wilayah Tengah) Malaysian Air Conditioning & Refrigeration Association (MACRA) President Dato' Andy Kwan was given an encouragement and support speech during the event which was organized with style.   CULMI AIR-COND & REFRIGERATION PARTS SUPPLY SDN. BHD. was one of the Sponsors for this program. 首届毕业礼 亿康学院26文凭生结业 https://www.enanyang.my/news/20200314/%E9%A6%96%E5%B1%8A%E6%AF%95%E4%B8%9A%E7%A4%BC-br%E4%BA%BF%E5%BA%B7%E5%AD%A6%E9%99%A226%E6%96%87%E5%87%AD%E7%94%9F%E7%BB%93%E4%B8%9A/amp/#aoh=15841733237353&referrer=https%3A%2F%2Fwww.google.com&_tf=From%20%251%24s EAKON ACADEMY VOCATIONL SKILLS TRAINING http://www.eakonacademy.edu.my/ read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Air-Cond and Refrigeration Tooling - DSZH
Mar 11, 2020 at 02:36 pm —
DSZH MINI TUBE CUTTER

DSZH MINI TUBE CUTTER

DSZH MINI TUBE CUTTER  Type DSZH WK-127 MINI TUBE CUTTER (O.D. 1/8''~5/8'' / 3~16MM) DSZH WK-128 MINI TUBE CUTTER (O.D. 1/8''~7/8'' / 3~32MM)   read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Pressure Washer - DELUXF
Mar 11, 2020 at 02:25 pm —
DELUXF 5.0 LITRE PLASTIC PRESSURE SPRAYER

DELUXF 5.0 LITRE PLASTIC PRESSURE SPRAYER

DELUXF 5.0 LITRE PLASTIC PRESSURE SPRAYER = RM55.00 PER PC (13-3-2024=AAA21.81818) Packing 6-PC/BOX   read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Parts, Components and Accessories - Danfoss
Mar 11, 2020 at 01:10 pm —
DANFOSS ROTALOCK VALVE

DANFOSS ROTALOCK VALVE

DANFOSS ROTALOCK VALVE Type (Individual) DANFOSS V01 SERVICE VALVE SET MT/MTZ 018-022, 028 8168027 (1'' ROTALOCK, 3/8'' ODF) DANFOSS V02 SERVICE VALVE SET MT/MTZ 080,100-125-144-160 8168028 (1-3/4” ROTALOCK, 1-1/8” ODF) DANFOSS V04 SERVICE VALVE SET MT/MTZ 44-160 8168029 (1-1/4” ROTALOCK, 3/4” ODF) DANFOSS V05 SERVICE VALVE SET MT/MTZ COMPRESSOR 8168030 (1-1/4” ROTALOCK, 7/8” ODF) DANFOSS V06 SERVICE VALVE SET MT/MTZ COMPRESSOR 8168031 (1” ROTALOCK, 1/2” ODF) DANFOSS V07 SERVICE VALVE SET MT/MTZ COMPRESSOR (1-3/4” ROTALOCK, 7/8” ODF) DANFOSS V09 SERVICE VALVE SET MT/MTZ COMPRESSOR 8168033 (1-1/4” ROTALOCK, 5/8” ODF) DANFOSS V10 SERVICE VALVE SET MT/MTZ COMPRESSOR 8168022 (1-3/4” ROTALOCK, 1-3/8” ODF)     Type (Set) DANFOSS V01-V06 7703004 SERVICE VALVE SETS (FOR MT28) DANFOSS V04-V02 7703009 SERVICE VALVE SETS   read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Parts, Components and Accessories - Mitsubishi (MHI)
Mar 11, 2020 at 01:01 pm —
MITSUBISHI (IMZ) SSA512T149 MOTOR FOR FDK36KXE6F

MITSUBISHI (IMZ) SSA512T149 MOTOR FOR FDK36KXE6F

MITSUBISHI (IMZ) SSA512T149 MOTOR FOR FDK36KXE6F   read more
next page