Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Refrigerant Leak Detection System - Bacharach (USA)
Aug 14, 2020 at 02:04 pm —
BACHARACH MGS-400 GAS DETECTION SERIES

BACHARACH MGS-400 GAS DETECTION SERIES

BACHARACH MGS-400 GAS DETECTION SERIES REPLACED BACHARACH MGS-150 Gas Detector 0-1000 PPM (STD R134a) BACHARACH MGS-400 GAS DETECTION SERIES Note The 400 series detectors has a nice telephone app where you can connect to phone and see gas readings. Model BACHARACH MGS-450 FIXED GAS DETECTOR (STD R134A) 0-1000PPM (IP41) P/NO:6302-1101 BACHARACH MGS-450 FIXED GAS DETECTOR (STD R404A) 0-1000PPM (IP41) P/NO:6302-1103 Spare Part BACHARACH SENS MOD, MGS-450, R134A SC 1K P/NO:6302-9101   Gas Detection Solution for Safety Compliance Mobile app interface for easy commissioning and maintenance without specialty tools Plug-and-play pre-calibrated sensor modules for quick, simple sensor replacement Temperature-compensated measurements mitigate false alarms and optimize accuracy in refrigeration applications Digital and analog communications for integration with BMS / BAS control systems Onboard A/V alarms for ASHRAE 15 and EN 378 compliance with no additional hardware Product Description Bacharach's MGS-400 Series Gas Detectors make compliance with refrigeration safety codes (e.g., ASHRAE 15 and EN 378) simple and easy, saving time and money on equipment and installation. Using the MGS-400 App (compatible with Android and iOS), users can intuitively use, commission and maintain their gas detection system without the need for specialty training or tools. Pre-calibrated sensor modules simplify maintenance, take minutes to exchange, and do not require the use of calibration gas. MGS-400 Series Gas Detectors allow installers to daisy-chain power (24V DC) and Modbus communication cables across the system, and can be easily integrated into a BMS / BAS, or with Bacharach's optional MGS-408 Gas Detection Controller. Product Specifications Gases and Ranges Refrigerants 1,000 ppm CO2 5,000 / 10,000 / 20,000 / 30,000 / 40,000 / 50,000 ppm NH3 100 / 1,000 / 5,000 ppm / 100% LEL O2 30 Vol% CO 500 / 1,000 ppm Combustible Gases - Semiconductor (R-290, R-600, CH4, R-600a, HC-12a, R-717) 5,000 ppm Combustible Gases - Catalytics (R-600, CH4, R-290, NH3 100% LEL NO2 20 ppm   read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Material Lifts - CULMI
Aug 12, 2020 at 11:07 am —
CULMI AIR COND OUTDOOR LIFTING TOOL SET QI-2 (MAX CAPACITY : 65KG / LIFTING HEIGHT : 24FT/7.317M)

CULMI AIR COND OUTDOOR LIFTING TOOL SET QI-2 (MAX CAPACITY : 65KG / LIFTING HEIGHT : 24FT/7.317M)

CULMI AIR COND OUTDOOR LIFTING TOOL SET QI-2 (MAX CAPACITY : 65KG / LIFTING HEIGHT : 24FT/7.317M)   read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo
Aug 12, 2020 at 09:01 am —
DUNHAMBUSH (TORIN) PZ4E660N30R10AA ROPELLER FAN (26IN/15.9MM)- (ACP5B250PQ)

DUNHAMBUSH (TORIN) PZ4E660N30R10AA ROPELLER FAN (26IN/15.9MM)- (ACP5B250PQ)

DUNHAMBUSH (TORIN) PZ4E660N30R10AA ROPELLER FAN (26IN/15.9MM)- (ACP5B250PQ)   read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Air-Conditioner Products - CARRIER
Aug 9, 2020 at 01:27 pm —
CARRIER WALL MOUNTED R32 (NON-INVERTER) & R410A (NON & INVERTER) BASIC & IONIZER FILTER

CARRIER WALL MOUNTED R32 (NON-INVERTER) & R410A (NON & INVERTER) BASIC & IONIZER FILTER

CARRIER WALL MOUNTED (HIWALL) R32 (NON-INVERTER) & R410A (NON & INVERTER) BASIC & IONIZER FILTER Model R32 FS (Fixed Speed Non Inverter) - Hiwall (Wall Mounted) CARRIER 1.0HP (9,000 BTU/HR) 38KHA009N8FS/42KHA009N8FS (R32) FS (NON-INV.) - HIWALL CARRIER 1.5HP (12,000 BTU/HR) 38KHA012N8FS/42KHA012N8FS (R32) FS (NON-INV.) - HIWALL  CARRIER 2.0HP (18,000 BTU/HR) 38KHA018N8FS/42KHA018N8FS (R32) FS (NON-INV.) - HIWALL CARRIER 2.5HP (24,000 BTU/HR) 38KHA024N8FS/42KHA024N8FS (R32) FS (NON-INV.) - HIWALL R410A FS (Fixed Speed Non Inverter) - Hiwall (Wall Mounted) (Ionizer Filter) CARRIER 1.0HP (9,000 BTU/HR) 38KHA009FS/42KHA009FS (R410A) FS (NON-INV.) - HIWALL (IONIZER FILTER) CARRIER 1.5HP (12,000 BTU/HR) 38KHA012FS/42KHA012FS (R410A FS (NON-INV.) - HIWALL (IONIZER FILTER) CARRIER 2.0HP (18,000 BTU/HR) 38KHA018FS/42KHA018FS (R410A FS (NON-INV.) - HIWALL (IONIZER FILTER) CARRIER 2.5HP (24,000 BTU/HR) 38KHA024FSA/42KHA024FSA (R410A FSA (NON-INV.) - HIWALL (IONIZER FILTER) CARRIER 2.75HP (27,000 BTU/HR) 38KHA027FS/42KHA027FS (R410A FS (NON-INV.) - HIWALL (IONIZER FILTER) CARRIER 3.2HP (32,000 BTU/HR) 38KHA032FS/42KHA032FS (R410A FS (NON-INV.) - HIWALL (IONIZER FILTER) R410A Inverter - Hiwall (Wall Mounted) (Basic) CARRIER 1.0HP (9,000 BTU/HR) 38KHA009VSA/42KHA009VSA (R410A) (INVERTER) - HIWALL (BASIC) CARRIER 1.5HP (12,000 BTU/HR) 38KHA012VS/42KHA012VS (R410A) (INVERTER) - HIWALL (BASIC) CARRIER 2.0HP (18,000 BTU/HR) 38KHA018VS/42KHA018VS (R410A) (INVERTER) - HIWALL (BASIC) CARRIER 2.2HP (22,000 BTU/HR) 38KHA022VS/42KHA022VS (R410A) (INVERTER) - HIWALL (BASIC) R410A Inverter - Hiwall (Wall Mounted) (Ionizer Filter) (Wifi Only 9,500 To 24,000 Btu/hr) CARRIER 1.0HP (9,500 BTU/HR) 38KHC009VSDC/42KHC009VSDC (R410A) (INVERTER) - HIWALL (IONIZER FILTER) (WIFI) CARRIER 1.5HP (12,000 BTU/HR) 38KHC012VSDC/42KHC012VSDC (R410A) (INVERTER) - HIWALL (IONIZER FILTER) (WIFI) CARRIER 2.0HP (18,000 BTU/HR) 38KHC018VSDC/42KHC018VSDC (R410A) (INVERTER) - HIWALL (IONIZER FILTER) (WIFI) CARRIER 2.5HP (24,000 BTU/HR) 38KHC024VSDC/42KHC024VSDC (R410A) (INVERTER) - HIWALL (IONIZER FILTER) (WIFI) CARRIER 3.0HP (30,000 BTU/HR) 38KHC030VS/42KHC030VS (R410A) (INVERTER) - HIWALL (IONIZER FILTER) The Difference Between R410A and R32 As if buying a new air conditioner isn’t already a tough choice, now we also have to decide between two different refrigerants as well. Of course, we’re talking about the well-established R410A and the newly introduced R32. We use the term “refrigerant” to refer to several types of gases that we use as cooling agents in air conditioners and other similar devices. The gases are insoluble in water and can travel as far up as the stratosphere, thanks to different chemical reactions. We differentiate between refrigerants based on: their chemical structure their environmental impact the type of device that uses them What makes certain refrigerants stand out is their impact on our environment. For example, both R32 and R410A belong to a group of gases called hydrofluorocarbons. Their ODP (ozone depletion potential) is 0, which makes them eco-friendly. Both refrigerants belong to the same group and share the same ODP. However, in this article, we will discuss their differences. Which one is better? Let’s find out. But first, here’s some general information about these two refrigerants.   What Is R410A? In 1991, an American company by the name of Allied Signal invented and patented the R410A refrigerant. Five years later, the gas found its way into residential air conditioning units, replacing R22 in the US, Japan, and Europe. In 2010, the US completely phased out R22. Since then, R410A has been the standard for all new air conditioners in the country. Unlike other refrigerants, R410A operates at much higher pressures. Therefore, handling it requires the use of equipment that is suitable for such conditions. Even though it consists of two different gases, it still has a constant boiling point. Because of that, refilling a pressure vessel with R410A should be relatively easy and without any leakage. In contrast to haloalkane refrigerants, R410A does not contain chlorine or bromine. Instead, the gas contains only fluorine, hence its non-existent ODP. That is the reason why R410A became widely available, replacing R22 in the process. While R22 has a global warming potential of 1810, R410A exceeds it with a GWP of 2088. However, the latter largely reduces power consumption. Therefore, its environmental impact is drastically lower than that of R22.   What is R32? R32, better known as difluoromethane, is an organic gas, much like R410A. With an ODP of 0, the two gases are also equally harmless to the ozone layer. Still, R32 has a GWP of 675, which is significantly lower than those of R22 and R410A. That makes it a seemingly better alternative. R32 performs well in terms of pressure drop and heat transfer. It’s a grade A2L gas, which means it is mildly flammable. In spite of that, R32 has been successfully used for many years now, most notably in China, India, and Japan. In order to mitigate the risk related to its flammability, experts recommend using heat transfer equipment that has a low refrigerant charge. Interestingly enough, R32 is a component found in other refrigerants. For example, by combining it with R125 and R143a, we can create refrigerants R407A and R407B (through E). R32 is also one of two gases that make up R410A, which we described above.   The Difference Between R410A and R32 Unlike R32, R410A has a low critical temperature, which in turn yields a lower coefficient of performance. Additionally, R32 is less dense than 410A. That makes its amount smaller per one charge. Given that we measure GWP per kg, R32 affects the climate even less than its GWP suggests. The two gases are also different in terms of their volumetric cooling capacity. R410A has a high VCP, which requires larger pipes. Thus, it’s not as efficient as R32, whose VCP is significantly lower. Moreover, R32 has a higher pressure ratio than R410A. Overall, R32 is much more efficient than R410A. However, it does have a few shortcomings as well, namely its high discharge temperature. Because of that, it can break down the oil in the system, which leads to bearing seizures. Fortunately, there is a way to limit the discharge temperature of R32 so that the system can function properly.   R410A and R32 — Which One Is Better? Everything we’ve said so far indicates that R32 is a clear winner of our comparison. Since R32 is a single-component gas, it is more convenient to work with and easier to recycle. Moreover, its low GWP and high COP make it the perfect candidate to drive R410A into obsolescence. According to several reports, most countries intend to phase out R410A by 2025. Still, some people contest the claims that R32 is the refrigerant of the future. They don’t deny its many benefits. However, they do claim that R32 is just another step toward finding the ultimate eco-friendly refrigerant. Additionally, many people worry about the flammable nature of R32. We hope that our article has shed some light on the differences between R410A and R32. In the end, time will only tell which one takes the “eco-friendly cake.”         read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added 4 new photos in Air-Cond and Refrigeration Tooling - CULMI
Aug 7, 2020 at 01:54 pm —
CULMI CT-128 MINI TUBE CUTTER (O.D. 1/8"~7/8" / 3~22mm)
CULMI CT-274 TUBE CUTTER (O.D. 1/8"~1-1/8" / 3~28mm)
CULMI CT-206 SPEED TUBE CUTTER (O.D. 1/4"~2-5/8" / 6~65mm)
CULMI CT-278 FLARING & SWAGING TOOL KIT 45° (O.D. 1/8"/3/16"/1/4"/5/16"/3/8"/7/16"/1/2"/5/8" & 3/4")
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Refrigerant Identifier - Neutronics
Jul 31, 2020 at 12:56 pm —
NEUTRONICS ULTIMA ID RI-700H PRO HVAC/R REFRIGERANT IDENTIFIER C/W PRINTER

NEUTRONICS ULTIMA ID RI-700H PRO HVAC/R REFRIGERANT IDENTIFIER C/W PRINTER

NEUTRONICS ULTIMA ID RI-700H PRO HVAC/R REFRIGERANT IDENTIFIER C/W PRINTER Accessories (FOC) For Setting Up 1) 1/4''SAE X 5/16''NPT FEMALE CONNECTOR FOR R134 GAS CYLD R-04X05 = 1PC 2) CULMI RW-341 CONTROL VALVE 1/4'' SAE (M) X 1/4'' SAE (F) (R22/R404A/R407C) = 1PC 3) CULMI RW-341B CONTROL VALVE 5/16'' SAE (M) X 5/16'' SAE (F) (R410A/R32) = 1PC 4) RU-410A ADAPTOR FOR R410A (FEMALE 5/16'' X MALE 1/4'') = 1PC 5) ELECTRICAL ADAPTOR 2-PIN 4-WAY = 1PC The Neutronics Ultima ID Pro™ Refrigerant Analyzer provides a fast, easy and accurate means to determine refrigerant purity in refrigerant storage cylinders or directly in air conditioning systems. The instrument utilizes non-dispersive infrared (NDIR) technology to determine the weight concentrations of multiple refrigerant types. Refrigerant purity is displayed on the LCD Screen and the user must determine acceptable levels of purity based on their recovery or use standards. The instrument is supplied complete with a ¼” Flare Vapor Sampling Hose, a High Pressure Liquid Sample Trap Assembly, a 100-240 VAC power transformer, built in Lithium Iron Phosphate battery, thermal printer, and all required plumbing housed within a rugged, portable, storage case. Testing occurs when sample gas is admitted into the instrument through the supplied sampling hose configurations and presented to the sensing device. The instrument provides the user with direct percent by weight concentrations.   The instrument interfaces with the user via a LCD graphic display, status indicator LED’s, and push button communication switches. Direct percent by weight concentrations of the sampled refrigerant are provided on the display as well as user directions and prompts. An on-board printer is provided to print an on-the-spot analysis report. The Neutronics Ultima ID Pro™ Refrigerant Analyzer provides the refrigerant technician with excellent knowledge of refrigerant type and purity as well as protection against refrigerant contamination and potential flammability. Specifications Weight: Less than 10 lb. Analyzed Refrigerants: R22, R32, R134a, R404A, R407C, R410a, Hydrocarbons (HC) and Air Identified Refrigerants: R12, R1234yf, R408A, R409A, R417A, R421A, R421B, R422A, R422B, R422C, R427A and Hydrocarbons (HC) Accuracy: +/- 2% of indicated gasses or better Power requirements: 12 VDC @ 2A via 110/220 VAC Adapter; Built-in rechargeable Battery pack (internal). Approvals: CE, UL, CUL User interface: Graphic display, soft keys, built in printer Sample gas extraction: Pressure from cylinder or system Temperature range: 50° to 120° F Response time: Less than 3 Minutes Humidity: 0-95% RH non-condensing Test sample size: 5g per test Test pressure: 50 psi – 500 psi Features   Advanced ergonomic design    Rugged rubberized hand grips  Large graphic display with on-screen instructions  Fast test time  Built in printer for instant analysis report  Built in oxygen sensor to detect presence of Air  Vapor or Liquid Sampling ability  Internal, rechargeable Lithium Iron Phosphate battery for cordless operation in any location  Hard shell carry/storage case  USB Port for Remote Software Updates Spare Replacement Parts NEUTRONICS ULTIMA ID RI-700H PRO THERMAL PAPER MASTERCOOL 69HVAC-FILTER FOR 69HVAC   read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Brazing Equipment and Accessories - HOSEFLEX
Jul 30, 2020 at 12:39 pm —
HOSEFLEX 1/4" RUBBER TWIN HOSE W/P : 20BAR (290PSI) (MADE IN MALAYSIA)

HOSEFLEX 1/4" RUBBER TWIN HOSE W/P : 20BAR (290PSI) (MADE IN MALAYSIA)

HOSEFLEX 1/4'' RUBBER TWIN HOSE W/P : 20BAR (290PSI) (MADE IN MALAYSIA) Type HOSEFLEX 1/4'' RUBBER TWIN HOSE X 10M / ROLL W/P : 20BAR (290PSI) (MADE IN MALAYSIA) HOSEFLEX 1/4'' RUBBER TWIN HOSE X 100M / ROLL W/P : 20BAR (290PSI) (MADE IN MALAYSIA)     read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Brazing Equipment and Accessories - MUREX
Jul 29, 2020 at 06:46 pm —
MUREX L/W WELDING TORCH COMPLETE WITH CHECK VALVE & 3 PCS TIP (YH) (NO. 1, 2 & 3)

MUREX L/W WELDING TORCH COMPLETE WITH CHECK VALVE & 3 PCS TIP (YH) (NO. 1, 2 & 3)

MUREX L/W WELDING TORCH COMPLETE WITH CHECK VALVE & 3 PCS TIP (NO. 1, 2 & 3)   read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added 2 new photos in Measuring Instrument - STANLEY
Jul 27, 2020 at 06:21 pm —
STANLEY STHT77-140 TLM330S (330 FT / 100M) TRUE LASER DISTANCE MEASURE
STANLEY STHT77-425 TLM30 (30 FT / 9M) LASER DISTANCE MEASURE (RECHARGEABLE BATTERY)
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Brazing Equipment and Accessories - GENTEC
Jul 24, 2020 at 04:46 pm —
GENTEC 591 SERIES HIGH PRESSURE PISTON REGULATORS

GENTEC 591 SERIES HIGH PRESSURE PISTON REGULATORS

GENTEC 591 SERIES HIGH PRESSURE PISTON REGULATORS Model 591 Series High Pressure Piston Regulators feature a reliable piston design for precise gas control at high inlet and delivery pressures rating up to 4500 PSIG. Like all GENTEC® quality products, the 591 Series provides superior performance and safety features. Features   • Piston-type construction • Body and housing cap are machined from class ''A'' brass • Delrin-cap bushing for smooth adjustments • Sintered bronze inlet filter • 1/4'' Stainless steel Compression-Tube Fitting (GENLOK™ ) Outlet • 2-1/2'' gauges • Weight: 4 lbs • Conforms to CGA E-4 standard for • gas pressure regulators Model GENTEC 591IN-4500 HIGH PRESSURE PISTON REGULATOR (SINGLE STAGE) (P/N:110246326) GENTEC 591IN-3000 HIGH PRESSURE PISTON REGULATOR (SINGLE STAGE) (P/N:110246325) Inlet Connection change to bs04 for H2 application   GENTEC 591IN-3000 INERT GAS (Ar, He, N2) HIGH PRESSURE PISTON REGULATOR (SINGLE STAGE) (P/N:110246325)   Gas Service - INERT GAS (Ar, He, N2) Maximum Inlet Pressure (PSI) - 5500  Maximum Delivery Pressure (PSI) - 300 - 4500 Product Link: https://www.genstartech.com/high-pressure-piston-regulators   read more
next page