Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added a news
Oct 16, 2016 at 10:48 am —
Montreal Protocol meet in Kigali to focus on phasing-out of planet-warming HFCs

Montreal Protocol meet in Kigali to focus on phasing-out of planet-warming HFCs

Montreal Protocol meet in Kigali to focus on phasing-out of planet-warming HFCs After a relatively quiet first half of the week, during which little forward movement was made, the Kigali meeting of the Montreal Protocol is welcoming ministers from across the world Thursday in a bid to get an ambitious agreement on the phase-out of planet-warming HFCs, a set of gases that are used extensively in the air-conditioning and refrigerant industry. The last two days of the meeting involves negotiations at the ministerial level and it is in Kigali that a breakthrough is being expected. US Secretary of State John Kerry is arriving in Kigali on Friday, the last day of the meeting, to be present when the countries, hopefully, announce yet another landmark agreement to fight climate change, something that the Barack Obama administration is extremely keen to sign off its term with. But before that, it would be the Indian Environment Minister Anil Madhav Dave who would decide how big the celebrations on Friday night, or Saturday, could be. India, which has a fast-growing air-conditioning and refrigerant industry, is the only major country to be still holding back from committing itself to early restrictions on HFC (hydrofluorocarbons) production and consumption. India wants its industry to be allowed to grow unhindered for another ten years, before it starts making the HFC-reductions. Other developing countries, including China, do not mind a faster time-line, beginning from 2020 or 2022. “India is the kingmaker here. It is the most crucial player right now,” said Durwood Zaelke, founder and president of Washington-based Institute for Governance and Sustainable Development. Though a relatively small contributor to global warming overall, accounting for about 5 per cent of total greenhouse gases, the use of HFCs is growing at about ten per cent annually. If left unabated, these are estimated to account for 19 per cent of all greenhouse gas emissions by the year 2050. But more importantly, the phase-out of HFCs by the year 2050 is estimated to prevent at least 0.5 degree of warming by the year 2100. Since this can be achieved by regulating a small group of industries, HFC phase-out is seen as a low-hanging fruit in the fight against climate change. In Kigali, countries are trying to finalise an amendment to the 1989 ozone-saving Montreal Protocol to enable it to monitor the phase-out of HFCs, which are not ozone-depleting. Montreal Protocol has been a highly successful international arrangement, having already phased-out more than 95 per cent of the ozone-depleting substances, its main mandate, in the less than 30 years of its existence. While everyone wants the Protocol to be amended, countries differ over the phase-down schedule for the HFCs. Developed countries have an early phase-down schedule, but there are disagreements over when the developing countries should start their phase-out. Countries have to decide on a baseline year, against which their future reductions would be measured. It is proposed that the developed world consider the average production and consumption in the years 2011-2013 as their baseline and reduce their HFC use by at least 10 per cent by the year 2019 from that value. India has been proposing 2024-2026 as the baseline years for developing countries like itself, but there are others who want this to be 2020-2022. China, and many other developing countries, agree to the 2020-2022 baseline, leading to fears that India might be completely isolated. The later the baseline years, the more time industry gets to make a switch from the HFCs to cleaner alternatives. © The Indian Express Online Media Pvt Ltd Written by Amitabh Sinha | Kigali | Updated: October 13, 2016 2:09 pm AMITABH SINHA PROFILE http://indianexpress.com/profile/author/amitabh-sinha/ Latest on 8-11-2020 Environment minister: Malaysia ratifies Kigali Amendment to Montreal Protocol to protect zone layer Sunday, 08 Nov 2020 07:46 PM MYT PUTRAJAYA, Nov 8 — Malaysia has ratified the Kigali Amendment to the Montreal Protocol on Substances that Deplete the Ozone Layer under the Vienna Convention for ozone layer protection. Environment and Water Minister Datuk Seri Tuan Ibrahim Tuan Man said the instrument of ratification has been deposited to the United Nations in New York on October 21 through the Foreign Ministry. “The ratification shows Malaysia’s commitment to protecting the environment, particularly the ozone layer in addressing climate change,” he said in a statement today. Kigali Amendment came into force on January 1, 2019 and to date, 110 countries have ratified the amendment to implement a phasedown of the consumption of hydrofluorocarbon (HFC), thereby mitigating negative impacts on climate change. He said HFC has a very high Global Warming Potential (GWP), which is up to 14,800 higher than carbon dioxide (CO2). Tuan Ibrahim said the amendment was agreed upon during the 28th Meeting of Parties of the Montreal Protocol, which was held on October 15, 2016 in Kigali, Rwanda. “Under the Kigali Amendment, Malaysia must reduce 80 per cent HFC consumption within the baseline by 2045. The consumption of HFC will be frozen at baseline in Malaysia starting on January 1, 2024. He said the government has started consultations on the ratification of the Kigali Amendment to Montreal Protocol with the relevant stakeholders including government agencies, non-governmental organisations and industries impacted by the phase-down of HFC consumption since early 2017. “The consulted industries include refrigeration and air conditioning, fire protection, solvent and other relevant sectors,” he said. In this case, he said successful implementation of HFC phase-down under the Kigali Amendment will help in reducing the impact of global warming and it is expected that greenhouse gas emission equivalent to 105 million tonne CO2 equivalent can be avoided by 2100, which will prevent the increase of global temperature by 0.5 degree Celsius. Tuan Ibrahim said the ratification will benefit Malaysia in terms of trade access with other country parties, financial assistance under the Multilateral Fund (MLF) and technical assistance for our local industries to convert to low carbon alternatives and technologies. “This will in turn, open up opportunities for the local industries to give rise to products that are able to compete within the global market in the future. “Malaysia joining the Kigali Amendment to the Montreal Protocol is a testimony of our continuous effort in working with the global community to address various environmental issues and challenges towards sustainable development,” he said. — Bernama   read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Measuring Instrument - TPI (Test Products International, USA)
Oct 13, 2016 at 05:03 pm —
TPI 510 Solar Irradiance Meter

TPI 510 Solar Irradiance Meter

TPI 510 Solar Irradiance Meter The TPI 510 is an easy to use, solar irradiance meter for measurement of not only solar radiation, but all measureable light sources including all visible light. The TPI Solar Meter is state of the art and easy to use. It is designed to measure solar power in W/m2 or BTU (ft2*h). Use to find the optimal angle of inclination for installing solar panels Measure light intensity through windows Determine the effectiveness of solar film / window tint Measure solar radiation (irradiance) Displays results in W/m2 or BTU 0 to 1999 W/m2 (0 to 634 BTU) range Min / Max and Data hold functions Model 510 Specifications  Range  1999W/m2 / 634BTU/(ft2*h)    Accuracy  Typically within ±10W/m2   [±3BTU/(ft2*h)] or ±5%, whichever is greater in sunlight;   Additional temperature induced error ±0.38W/m2/°C   [±0.12BTU/(ft2*h)/°C] from 25°C    Display  3-1/2 digits LCD with maximum reading 1999  Sampling Time  Approx. 0.25 second  Resolution  0.1W/m2 / 0.1BTU/(ft2*h)  Over-Input  Display shows" OL".  Operating Temp. & RH  41°F~104°F (5°C~40°C), below 80%RH.  Storage Temp. & RH  14°F~140°F (-10°C~60°C), below 70% RH    Dimensions & Weight:  5.1 x 2.4 x 1.5” 5.3oz   (132 x 60 x38 mm, approx. 150g)     EMC  This instrument is EMC-compliant and has undergone compatibility   tests according to EN61326 (1997) + A1 (1998) + A2 (2001)    Accessories  • User Manual   • A9V battery(NEDA 1604 IEC 6F 22 JIS 006P)*1   • Carrying Case read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Parts, Components and Accessories - Honeywell
Oct 12, 2016 at 06:59 pm —
HONEYWELL VS4016 SERIES  MOTORIZED ON/OFF VALVE

HONEYWELL VS4016 SERIES MOTORIZED ON/OFF VALVE

HONEYWELL VS4016 SERIES  MOTORIZED ON/OFF VALVE Spring Return Type Spring return VC valve is one type of control valve that can do precise control refer to customer’s demands. Spring return actuator has the special function that if the power is off, the valve will return to original position by spring. This is a safe and energy saving function to customers.   Type (Complete Set) HONEYWELL VS4016AJ1000T ACTUATOR (2-WIRE/220V 50/60HZ) C/W 2-WAY 3/4'' BSPP (INT) VALVE HONEYWELL VS4016AK1000T ACTUATOR (2-WIRE/220V 50/60HZ) C/W 2-WAY 3/4'' BSPT (INT) VALVE Actuator Only HONEYWELL VS4016ZZ ACTUATOR (2-WIRE/220V 50/60HZ) Valve Only HONEYWELL VS4016AJ (VSZAJ) -3/4'' 2-WAY SR MOTORISED FCU VALVE   Note All Honeywell Products sold has a one year warranty based on Material & Workmanship defects. (18-10-2024)     Replacement Model HONEYWELL V4043C1362B 2-WAY (BSPP 3/4'') FAN COIL VALVE (SPRING RETURN) http://www.culmi.com.my/index.php?ws=showproducts&products_id=906100&cat=Parts-Components-and-Accessories&subcat=Honeywell#openproducts HONEYWELL VC4013AJ1000T ACTUATOR (2-WIRE+COM./200-240V 50/60HZ) C/W 2-WAY 3/4'' BSPP VALVE (NON-SPRING RETURN) http://www.culmi.com.my/index.php?ws=showproducts&products_id=971980&cat=Parts-Components-and-Accessories&subcat=Honeywell#openproducts read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added a news
Oct 12, 2016 at 10:04 am —
Mr. Shuji Nakame and Mr. Akihiko Sato (Japan Sun Oil Company [SUNOCO] Visit On 11-10-2016

Mr. Shuji Nakame and Mr. Akihiko Sato (Japan Sun Oil Company [SUNOCO] Visit On 11-10-2016

Mr. Shuji Nakame and Mr. Akihiko Sato (Japan Sun Oil Company [SUNOCO] Visit On 11-10-2016 Culmi Air-Cond & Refrigeration Parts Sdn. Bhd. represented JAPAN SUN COIL COMPANY, LTD. for Malaysian market with their reputed high quality SUNISO COMPRESSOR LUBRICATING OILS since the year of 2015 and since then the acceptance of the Industry Players are with positive manner. On 11-10-2016, Executive Director of Sunoco (Thailand) Co., Ltd. Mr. Shuji Nakame and Mr. Akihiko Sato (Overseas Sales Group 2) Visited Culmi's office to express his appreciation on the Business Cooperation between CULMI AIR-COND and JAPAN SUN COIL COMPANY, LTD. to promote and market their JAPAN SUNISO OILS for Malaysian market. They took this opportunity to further enhance the product knowledge with his technical sharing and made new product introduction such as:- 1) SUNISO 4SA - For Ice Machine using R-717 (Ammonia) 2) SUNISO 4HT - For Cold Room using R-717 (Ammonia) New packaging of the product was highlighted again with more impressive oulook and with market trends approach. The product name of SUNISO for POE type such as SL-32S / 68S / 100S / 170S / 220S changed to Sunice was deliberated over again. 1) SUNISO Mineral Oil (3GS / 4GS / 5GS) Remained no change 2) SUNISO POE Oils (SL-32S / 68S / 100S / 170S / 220S) will be changed to Sunice  Product Link: 1)SUNICE Synthetic Refrigeration Oils (JAPAN) http://www.culmi.com.my/index.php?ws=showproducts&products_id=1137554&cat=Lubricant%20Oil%20and%20Equipment&subcat=Sunice#openproducts 2)SUNISO GS Series (3GS / 4GS / 5GS / 4SA / 4HT) Refrigeration Oils (SUNOCO JAPAN) New Packaging http://www.culmi.com.my/index.php?ws=showproducts&products_id=1148854&cat=Lubricant%20Oil%20and%20Equipment&subcat=SUNISO%20(SUNOCO%20Japan)#openproducts read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Lubricant Oil and Equipment - SUNISO (SUNOCO Japan)
Oct 12, 2016 at 09:22 am —
SUNISO GS Series (3GS / 4GS / 5GS / 4SA / 4HT) Refrigeration Oils (SUNOCO JAPAN) New Packaging

SUNISO GS Series (3GS / 4GS / 5GS / 4SA / 4HT) Refrigeration Oils (SUNOCO JAPAN) New Packaging

SUNISO GS Series (3GS / 4GS / 5GS / 4SA / 4HT) Refrigeration Oils (SUNOCO JAPAN) New Packaging Type and Packaging (NEW) SUNISO 3GS X 4L (6x4L can) REFRIGERANT OIL - SUNOCO JAPAN = RM90.00 PER CAN (9-10-2023=AAA17.777) (EQUAL TO DANFOSS 160P MINERAL OIL) SUNISO 4GS X 4L (6x4L can) REFRIGERANT OIL - SUNOCO JAPAN = RM90.00 PER CAN (9-10-2023=AAA17.777) SUNISO 5GS X 4L (6x4L can) REFRIGERANT OIL - SUNOCO JAPAN SUNISO 3GS X 20L REFRIGERANT OIL - SUNOCO JAPAN = RM415.00 PER PAIL (9-10-2023=AAA20.4819) (EQUAL TO DANFOSS 160P MINERAL OIL) SUNISO 4GS X 20L REFRIGERANT OIL - SUNOCO JAPAN = RM415.00 PER PAIL (9-10-2023=AAA20.4819) SUNISO 5GS X 20L REFRIGERANT OIL - SUNOCO JAPAN SUNISO 4SA X 20L REFRIGERANT OIL FOR R-717 (Ammonia) - SUNOCO JAPAN * Special Order! SUNISO 4SA X 200L (DRUM) REFRIGERANT OIL FOR R-717 (Ammonia) - SUNOCO JAPAN  SUNISO 4HT X 20L REFRIGERANT OIL FOR R-717 (Ammonia) - SUNOCO JAPAN * Special Order! SUNISO GS Oils are premium quality oils expressly designed for use as refrigeration compressor lubricants. SUNISO GS Oils are miscible well with HCFC and CFC refrigerants such as R-22, R-502 and R-12 while featuring excellent stability and giving long trouble-free service life in the refrigeration systems using above refrigerants. In addition, SUNISO GS Oils also perform excellently with natural refrigerants such as R-717, R-600a and R-290. SUNISO GS Oils are refined from specially selected naphthenic crude oils by special method assuring excellent lubricity and other properties. SUNISO GS Oils are approved by all major air-conditioner, refrigerator, freezer, car air-conditioner manufacturers in the world. Chemical Stability To resist chemical reaction with the refrigerant or other material normally present in the system. Thermal Stability To eliminate excessive carbon deposits at compressor hot spots such as valves or discharge ports. Low Wax Content To prevent separation of flocculant wax from the oil-refrigerant mixture at the low temperature points in the system. Low Pour Point To prevent separated oil from congealing in refrigerant lines. High Dielectric Strength To insure good insulating properties. In hermetic units, the oil-refrigerant mixture serves as an insulator between the motor and the compressor body. Proper Viscosity Even when diluted with refrigerant so as to insure high film strength at elevated operating temperatures and while providing good fluidity under coldest operating conditions. No Contamination To prevent scarring of bearing surfaces, plugging of lines or oil ports and general deterioration.   SUNISO GS Oils Conventional Oils Sealed Tube Test Terms : 175°C x 14days Catalyst : Fe, Cu, Al Refrigerant : R-12 SUNISO GS Oils feature excellent chemical stability.   Floc Test 3GS at -50°C Refrigerant : R-12 SUNISO GS Oils don't precipitate wax deposit in an extremely low temperature section of the system such as valve or evaporator.   Pour Point 3GS at -40°C SUNISO GS Oils are featuring outstanding fluidity at a low temperature condition resulting good oil returning in the refrigeration systems. TYPICAL DATA Property SUNISO 3GS SUNISO 4GS SUNISO 5GS Density 15°C g/cm3 0.909 0.915 0.921 Color ASTM   L0.5 L1.0 L1.0 Viscosity 40°C mm2/s 29.5 54.9 94.6 Viscosity 100°C mm2/s 4.31 5.97 7.78 Flash Point COC °C 178 188 208 Pour Point   °C -40 -35 -27.5 Total Acid No.   mgKOH/g 0.01 0.01 0.01 Aniline Point   °C 75.4 79.8 80.4 Water   ppm 20 20 20 Floc Point   °C -53 -46 -35 For the after-market and service field, Suniso GS Oils are available in 200L Drum and 20L Pail Can. Special package of Carton Case (4L Can x 6) is also available. *Suniso is a trademark of Sonneborn Inc. read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Brazing Equipment and Accessories - MUREX
Oct 11, 2016 at 04:08 pm —
MUREX ACETYLENE AND OXYGEN FLASHBACK ARRESTOR

MUREX ACETYLENE AND OXYGEN FLASHBACK ARRESTOR

MUREX ACETYLENE AND OXYGEN FLASHBACK ARRESTOR Type MUREX FLW-VFA-83RF ACETYLENE FLASHBACK ARRESTOR (1.5BAR/21PSI) MUREX FLW-VFA-83RO OXYGEN FLASHBACK ARRESTOR (10BAR/150PSI) Connection 3/8" brass TAIL NUT & NIPPLE read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Parts, Components and Accessories - Castel
Oct 8, 2016 at 09:20 am —
Castel Safety Valve

Castel Safety Valve

Castel Safety Valve Type CASTEL 3060/23C240 (1/4'' NPT [IN MALE] X 3/8'' SAE [OUT MALE]) 24BAR ANGLE SAFETY VALVE (ITALY)  CASTEL 3060/23C300 (1/4'' NPT [IN MALE] X 3/8'' SAE [OUT MALE]) 30BAR ANGLE SAFETY VALVE (ITALY)  CASTEL 3060/33C250 (3/8'' NPT [IN MALE] X 3/8'' SAE [OUT MALE]) 25BAR ANGLE SAFETY VALVE (ITALY)  CASTEL 3060/34C300 (3/8'' NPT [IN MALE] X 1/2'' SAE [OUT MALE]) 30BAR ANGLE SAFETY VALVE (ITALY)  CASTEL 3060/45C240 (1/2'' NPT [IN MALE] X 5/8'' SAE [OUT MALE]) 24BAR ANGLE SAFETY VALVE (ITALY)  CASTEL 3060/45C250 (1/2'' NPT [IN MALE] X 5/8'' SAE [OUT MALE]) 25BAR ANGLE SAFETY VALVE (ITALY)  CASTEL 3060/45C300 (1/2'' NPT [IN MALE] X 5/8'' SAE [OUT MALE]) 30BAR ANGLE SAFETY VALVE (ITALY)        SAFETY VALVES 3060 GENERAL DESCRIPTION Valves series 3060 are safety devices according to the definition given in Article 1, Point 2.1.3, 2nd dash of 97/23/ EC Directive and are the subject of Article 3, Point 1.4 of aforesaid Directive. The valves above mentioned are standard type, unbalanced, direct-loaded safety valves. Valve opening is produced by the thrust the fluid under pressure exerts on the disc, when said thrust exceeds, under setting conditions, the opposing force of the spring acting on the disc. Valves are identified by means of: • a model number formed of an alphanumerical coding that includes: • in the first part the family identification (e.g. 3060/45C) • in the second part the setting pressure, expressed in bars, multiplied by 10 (e.g. 140) • an alphanumerical serial number. SCOPE Use: protection against possible overpressures of the apparatuses listed below, with regard to the operating conditions for which they have been designed: • Refrigerating system and heat pump components, for instance: condensers, liquid receivers, evaporators, liquid accumulators, positive displacement compressor discharge, heat exchangers, oil separators, piping. (reference: EN 378-2:2008 Standard) • Simple pressure vessels (reference: 87/404/ EEC Directive)  read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Parts, Components and Accessories - York
Oct 6, 2016 at 03:32 pm —
YORK HAF-067 (1PH 1/4HP 140W 6P) INDOOR FAN MOTOR C/W 6UF CAPACITOR - (DCP06CC)(REPLACED:DE2J042K-1/5HP)

YORK HAF-067 (1PH 1/4HP 140W 6P) INDOOR FAN MOTOR C/W 6UF CAPACITOR - (DCP06CC)(REPLACED:DE2J042K-1/5HP)

YORK HAF-067 (1PH 1/4HP 140W 6P) INDOOR FAN MOTOR C/W 6UF CAPACITOR - (DCP06CC)(REPLACED:DE2J042K-1/5HP) read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Parts, Components and Accessories - Honeywell
Oct 5, 2016 at 06:16 pm —
HONEYWELL ML7421A8035-E 24V 50/60HZ DIRECT COUPLED ELECTRIC VALVE ACTUATOR

HONEYWELL ML7421A8035-E 24V 50/60HZ DIRECT COUPLED ELECTRIC VALVE ACTUATOR

HONEYWELL ML7421A8035-E 24V 50/60HZ DIRECT COUPLED ELECTRIC VALVE ACTUATOR  Note ML7421A8035 can be used up to a max 3'' valve only What is a Modulating Control Valve? A modulating control valve is an automated valve that is used to control the amount of flow in a system or process. They go beyond simple shutoff or isolation (on/off) and actually allow precise control of the flow rate. The actuators on these valves use feedback and control signals to accurately open and close the valve.  Note 1) ML7421A is for big valve.Torque is 1,800Nm. ML7420A8088A is for 1.5'' and below. Torque is 600Nm. 2) Pls note that there is no performance warranty on ML7420A with V5011P1038 (2'' 2-Way). It may not be strong enough to close the valve after a while. 3) All modulating actuators/thermostats are automatically 24Vac. This is industry standard. Note Replaced ML7421A1032 model Replaced ML7421A3004 model Replaced ML7421A1008 model Complete Set HONEYWELL V5013P1028 DN50 2'' 3-WAY BRONZE AHU VALVE C/W ML7421A8035-E MODULATING ACTUATOR HONEYWELL V5329A2077 DN65 2-1/2'' 3-WAY VALVE + ML7421A8035-E 24V ELECTRICAL VALVE ACTUATOR HONEYWELL V5329A 2-1/2'' 3-WAY CI AHU VALVE C/W ML7421A (1,800N) MODULATING ACTUATOR * Note: ML7984A (710N) is not recommended for 2.1/2'' 3 way valve. Torque not strong enough.  V5329A/ML7421A- 3'' 3 Way valve c/w mod actuator  V5328A/ML7421A - 3'' 2 way valve c/w mod actuator New Combination With New Valve Types The valve for 3'' 3-Way is V5GV3W080F and the valve for 2-Way is V5GV2W080F. You can still use back the same ML7421A Actuator   GENERAL   The ML7421A / ML7421B actuators are designed for modulating control, accepting 0(2)...10v or 4...20mA input signal, and providing feedback signal 2...10 Vdc only. They operate Honeywell’s standard valves in heating, ventilation, and air conditioning (HVAC) applications. FEATURE    Easy and quick installation  No separate linkage and adjustments required  Low power consumption and maintenance-free  Self-adaption function  Force-limiting end stops  Manual operation knob  0(2)~10 Vdc input and 2~10 Vdc position feedback  Direct/ Reverse action adjustable  Selectable stroke position when signal failure  Corrosion-resistant design SPECIFICATION   Temperature   Ambient operating -10~+50℃ at 5~95% r.h. Ambient storage -40...+70 °C at 5...95% r.h. Medium temperature 150 °C max. (220 °C with High-Temperature kit)   Signals   Signal input y=0(2)~10 Vdc or 4~20 mA Input impedance for voltage Ri=100 KΩ for mA Ri=500Ω Position feedback signal x=2~10Vdc Output impedance 1 KΩ max. Output load 1 mA max.   Safety   Protection class III as per EN60730-1 Protection standard IP54 as per EN60529 Flame retardant housing V0 as per UL94 (with metal cable gland)   Material   Cover ABS-FR Yoke and Base Aluminum die-cast read more
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd added new photo in Measuring Instrument - Mastercool
Oct 5, 2016 at 09:23 am —
MASTERCOOL 69HVAC-PRO2 ULTIMA ID PRO 2 HVAC REFRIGERANT IDENTIFIER

MASTERCOOL 69HVAC-PRO2 ULTIMA ID PRO 2 HVAC REFRIGERANT IDENTIFIER

THIS PRODUCT HAD DISCONTINUED AND BEING REPLACED WITH NEW MODEL OF:   69LEGEND-HFC LEGEND SERIES™ HFC REFRIGERANT ANALYZER https://www.mastercool.com/product/69legend-hfc/ 69HVAC-PRO2 ULTIMA ID™ PRO 2 HVAC REFRIGERANT IDENTIFIER   MASTERCOOL 69HVAC-PRO2 ULTIMA ID PRO 2 HVAC REFRIGERANT IDENTIFIER C/W PRINTER   Accessories (FOC) For Setting Up   1) 1/4''SAE X 5/16''NPT FEMALE CONNECTOR FOR R134 GAS CYLD R-04X05 = 1PC 2) CULMI RW-341 CONTROL VALVE 1/4'' SAE (M) X 1/4'' SAE (F) (R22/R404A/R407C) = 1PC 3) CULMI RW-341B CONTROL VALVE 5/16'' SAE (M) X 5/16'' SAE (F) (R410A/R32) = 1PC 4) RU-410A ADAPTOR FOR R410A (FEMALE 5/16'' X MALE 1/4'') = 1PC 5) ELECTRICAL ADAPTOR 2-PIN 4-WAY = 1PC Product Description The Ultima ID Pro 2 HVAC/R Refrigerant Analyzer enables fast, accurate testing of refrigerant, reducing the need for costly and time-consuming gas chromatography. Improved accuracy and the ability to test for a wide variety of refrigerants make this an essential tool for pre-screening refrigerant prior to consolidation and reclamation. Key Features:   Oil contamination resistant Fast test results Internal thermal printer Greater accuracy in less time Wide refrigerant range Refrigerant composition breakdown Remote software updates for new refrigerants Vapor or liquid sample analysis 1/4″ Flare sample hose SPECIFICATIONS:   Weight: Less than 10 Lbs. Analyzed Refrigerants: R22, R32, R134a, R404A, R407C, R410a, Hydrocarbons (HC) and Air Identified Refrigerants: R12, R1234yf, R408A, R409A, R417A, R421A, R421B, R422A, R422B, R422C, R427A and Hydrocarbons (HC) Accuracy: +/- 2% of indicated gasses or better Power Requirements: 12 VDC @ 2A via 110/220 VAC Adapter Approvals: CE, UL and CUL User Interface: Graphic display, soft keys, built in printer Sample Gas Extraction: Pressure from cylinder or system Temperature Range: 50 to 120˚F Humidity: 0-95% RH non-condensing Response Time: Less than 3 minutes Test Sample Size: 5 g per test Test Pressure: 50 psi – 500 psi Spare Replacement Parts MASTERCOOL 69HVAC-PR PRINTER ROLL FOR 69HVAC MASTERCOOL 69HVAC-FILTER FOR 69HVAC   read more