- Actuator
- Air Cleaner / Air Purifier
- Air Compressor Parts, Components and Accessories
- Air Cond Bracket
- Air Filter
- Air Purifier
- Air-Cond and Refrigeration Tooling
- Air-Conditioner Products
- Air-Curtain
- Anti-Clog
- Belting
- Best Seller
- Blower
- BRAZED PLATE HEAT EXCHANGER (BPHE)
- Brazing Alloys and Fluxes
- Brazing Equipment and Accessories
- Chemical
- Cleaning Cover
- Coldroom Parts and Accessories
- Company Developments
- Compressor
- Condensate Drainage Pump
- Condensing Unit
- Cooling Tower And Spare Parts
- Copper and Fittings
- Copper Piping Leak Test
- Cotton Rags
- Dehumidifier
- Delivery Service
- Ducting, Diffuser and Accessories
- Electrical
- ABB
- Amber
- ANLY
- BITZER
- BLACK + DECKER
- Camelion
- CARRIER
- China
- CIKACHI
- CKC
- CROWN
- DB
- DEER
- EATON
- ECOSTAR
- FAJAR
- GRAND HOLLY
- Hager
- HL
- HUPLIK
- IDEC
- LAPP Cable
- LEGRAND
- Local
- LS
- MEGA
- MK BY HONEYWELL
- OMRON
- PATLITE (JAPAN)
- PLUS CABLE
- PNT
- REGIN
- Schneider
- STANLEY
- SUM
- SWISSMEC
- TAIAN
- TEWC KABEL
- UMS
- UNITRONIC
- Yogawa
- York
- View All
- Exhaust and Ventilating Fan
- Export
- Fan Set
- Freezer
- Freezer Chiller (CDU)
- Hardware Items and Tools
- 3M
- ACE
- Alseal
- ANTON
- Apollo
- BERRYLION
- BINA
- China
- COSIMO
- COSTA
- DEWALT
- DIY
- Donson
- Enstar
- Forest
- FRONTIER
- FUJI
- Greenland
- HARDEX
- HELLO
- INGCO
- JINMA
- JOYF-AMILY
- Kelflex
- Ladder Technology
- Local
- Marksman
- Meko
- NEXUS
- NIH
- NIKI
- NISSHO
- NIYO
- PRESTAR
- PROGUARD
- ProsKit
- ROCKEY
- Rothenberger
- Scotch Brite
- Sheetrock
- SHELL
- Sin Harp
- STANLEY
- Statheros
- Sun eye
- Swelock
- SYW
- Takka
- Thing
- TOP BULL
- TOYO
- WELL MARK
- WIREMAN
- WORTH
- XR
- YATO
- ZEN
- View All
- Heat Reclaim
- Heater
- Horizontal Vertical Freezer
- INABA Installation Materials
- Inspection Equipment
- Insulation
- Lab Equipment
- Leak Stop Solution
- Lubricant Oil and Equipment
- Material Lifts
- Measurement
- Measuring Instrument
- CENTER
- TPI (Test Products International, USA)
- Bacharach (USA)
- China
- Dwyer
- Elitech
- Extech
- FLOWHOOD
- Fluke
- Foretech
- HANS
- HIOKI
- HONEYWELL
- Johnson Controls (JCI)
- K1
- Kyoritsu (Japan)
- Local
- LONGRUN
- LUTRON
- Mastercool
- Neutronics
- P and M
- Panasonic
- ProsKit
- Pulsar
- Refco
- Robinair
- Sanwa (Japan)
- STANLEY
- SYSTEM SENSOR
- TASCO
- TDS Testr
- TENMARS
- testo
- UNI-T
- Value
- Zeal
- View All
- Medical
- Oil Pump
- Parts, Components and Accessories
- Acson
- AIRMENDER
- ANACONDA
- AYVAZ
- Bitzer
- BLUE
- Bock
- Bristol
- Carrier
- Castel
- China
- Copeland
- Copeland Scroll
- CULMI
- Daikin
- Daikin (York)
- Danfoss
- DEWPOINT
- DJE (TAIWAN)
- DONPER
- Dunham-Bush
- EBM
- ELCO
- Emerson
- FASCO
- FRIMEC
- Fujiaire
- Fujikoki
- Fujitsu
- genteq
- GOLDEN
- GP Valve
- grefac
- HaiLin
- HELDON
- Henry
- Highside Chemicals
- Hitachi
- Honeywell
- HUB
- I-MAX
- INNERCO
- ISO
- JOHNSON CONTROLS
- KAWA
- KEMET
- KRIWAN
- Kruger
- KULTHORN KIRBY
- Local
- Magnetek
- MALLORY
- Maneurope
- Master Tool
- MIDEA
- Mitsubishi
- Mitsubishi (MELCO)
- Mitsubishi (MHI)
- NGM
- Nicotra
- Nitto
- OKM
- OMRON
- P and B
- P and M
- Packless
- Panasonic
- PRO-TEN
- Refco
- RefComp
- Refworld
- REGIN
- Saginomiya
- SANHUA
- SANYO
- Secop
- SEKI
- Shimatec
- SMARTECH
- SNOWICE
- SPORLAN
- SUN EYE
- SUNWHA
- TASCO
- TECO
- Tecumseh
- TEIDAR
- TEXAS
- Topaire
- TORIN
- Toshiba
- Tozen (Japan)
- Trane
- Vibratech
- Welcold
- WELCOME
- York
- York (AP)
- York (China)
- York (JCI)
- York Malaysia
- York/McQuay
- ZICO
- Others
- View All
- Pressure Test Equipment and Accessories
- AFA
- BELIMO
- BLUE
- CARRIER
- China
- COOLMAX
- CULMI
- Danfoss
- DSZH
- Dwyer
- Elitech
- FIVALCO
- GM (GAS CONTROL)
- grefac
- Harris
- HELDON
- HERO
- HK INSTRUMENTS
- Honeywell
- James
- JOHNSON CONTROLS
- Local
- Master Tool
- Mastercool
- MESSER
- MUREX
- OZWELD
- P & M
- PENN
- Refco
- Refworld
- Regin
- Robinair
- Rothenberger
- Sun eye
- TASCO
- Tozen (Japan)
- TS
- Value
- VESS
- Others
- View All
- Pressure Washer
- Project and Customer Reference
- Refrigerant
- Refrigerant Identifier
- Refrigerant Leak Detection System
- Refrigerant Recovery and Recycling Equipment
- Refrigeration Condensing Unit and Cooler (Blower)
- Repair
- Sealant
- SILICONE SEALANT
- Steam Cleaner
- SUN EYE
- System Flushing
- Temperature & Humidity Display / Controller
- Temperature and Humidity Display / Controller
- Temperature Display / Controller
- Tube Cleaning Equipment
- Vacuum Cleaner
- Vacuum Pump
- Valves (Water and Steam Application)
- Vibration Meter
- Water Heater
- Others
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd
24, Jalan Industri USJ 1/5,
Taman Perindustrian USJ 1,
47600 Subang Jaya,
Selangor, Malaysia.
+603-8024 7376
+603-8081 3378
+603-8024 7387
VALUE VRD Industrial Rotary Vacuum Pump
Previous | 5 / 5 | Next |
Rotary Vane Pump Animation
Download Files
Value_VRD-30_Product_Catalogue_(27-7-2023).pdf (45.64 KB)ROTARY_(VANE)_VACUUM_PUMP_OPERATION.pdf (155.32 KB)
VRD_Value_Industrial_Vacuum_Pump_Manual_(Part_2)_15-8-15.pdf (6.89 MB)
VRD_Value_Industrial_Vacuum_Pump_Manual_(Part_1)_15-8-15.pdf (5 MB)
Value_Industrial_Vacuum_Pump_VRD_Model_(27-2-15).jpg (133.02 KB)
Value_VRD-30_Rotary_Vacuum_Pump_Installation.pdf (792.36 KB)
2012_VRD_Catalogue.pdf (5.51 MB)
Value_VRD_Industrial_Rotary_Vacuum_Pump.pdf (70.43 KB)
VALUE VRD Industrial Rotary Vacuum Pump
Model Available
Optional Item
NW-40 (Tube Dia. 1-1/2'' Or 38mm) Long Flange
NW-25 (Tube Dia. 1'') Long Flange
https://www.htcvacuum.com/en-global/product/index/vacuum-components/vacuum-flanges/kf-nw-flanges/half-nipple-long
Accessories
Excellent Performance
The purpose of a vacuum pump is to remove moisture and air from an A/C-R system. Modern systems are built tighter and charges are more critical. That means these systems have a greater sensitivity to moisture and other contaminants, making thorough evacuation more important than ever before.
Moisture in a refrigeration system, directly or indirectly, is the cause of most problems and complaints. First, moisture can cause freeze-up in a system. Moisture is picked up by the refrigerant and transported through the refrigerant line in a fine mist, with ice crystals forming at the point of expansion.
“Freeze-up” is not the only problem caused by moisture. It can also result in corrosion, the effects of which are not apparent until the real damage has occurred.
Moisture alone is bad enough, but combined with refrigerants containing chlorine, hydrochloric acids can form. These greatly increase the corrosion of metals.
Also, refrigerant oil rapidly absorbs moisture. Water-formed acids combine with the refrigerant, forming a closely bonded mixture of fine globules.
The effect is called sludging and it greatly reduces the lubricating ability of the oil.
A vacuum pump removes troublesome moisture by lowering the pressure within the system and vaporizing (or boiling off) the moisture, then exhausting it along with air.
Operation
It can continue work 10-14hours without stop. But please make sure sufficient oil.
Model Available
- VALUE VRD-16 (1PH [0.75KW Or 1HP]/3PH [0.55KW Or 0.74HP]) (9.32 CFM) Rotary Vacuum Pump
- VALUE VRD-24 (1PH [0.75KW Or 1HP/3PH [1.1KW Or 1.48HP) (14 CFM) Rotary Vacuum Pump
- VALUE VRD-30 (1PH/3PH [1.1KW Or 1.48HP]) (17.655 CFM) Rotary Vacuum Pump = RM9,123.00 per unit (8-9-24=AAA34.180) (1-6-2024=30.00569)
- VALUE VRD-48 (3PH [1.5KW Or 2.0HP) (28.3 CFM) Rotary Vacuum Pump
- VALUE VRD-65 (3PH [2.2KW Or 2.95HP) (38.14 CFM) Rotary Vacuum Pump
Optional Item
NW-40 (Tube Dia. 1-1/2'' Or 38mm) Long Flange
NW-25 (Tube Dia. 1'') Long Flange
https://www.htcvacuum.com/en-global/product/index/vacuum-components/vacuum-flanges/kf-nw-flanges/half-nipple-long
Accessories
DN-25 KF ALUMINUM CLAMPING RING FOR VACUUM PUMP
DN-25 KF CENTERING RING WITH VITON ORING FOR VACUUM PUMP
Spare Parts
Spare Parts
VALUE RUBBER MOUNTING COUPLING FOR VRD-65 3PH ROTARY VACUUM PUMP
VALUE VRD-30 VACUUM PUMP BODY (SPARE PART)
VALUE VRD-30 VACUUM PUMP FAN MOTOR
- Integrated cylinder structure and high precision design to ensure the pump is able to work reliably in various conditions
- Constant oil supply pressure system is utilised to maintain the lubrication quality of the oil as well as the reliability of the internal seals. Both measures have been taken to further enhance the reliability and the durability of the vacuum pump.
- Automatic anti-backflow valve design, to protect the vacuum pump system from the contamination of the oil and the oil vapour after the pump has been stopped.
- Double gas ballast, meet the different requirements of steam exhaustion.
- Imported oil and fluororubber seals to suit different working conditions
The purpose of a vacuum pump is to remove moisture and air from an A/C-R system. Modern systems are built tighter and charges are more critical. That means these systems have a greater sensitivity to moisture and other contaminants, making thorough evacuation more important than ever before.
Moisture in a refrigeration system, directly or indirectly, is the cause of most problems and complaints. First, moisture can cause freeze-up in a system. Moisture is picked up by the refrigerant and transported through the refrigerant line in a fine mist, with ice crystals forming at the point of expansion.
“Freeze-up” is not the only problem caused by moisture. It can also result in corrosion, the effects of which are not apparent until the real damage has occurred.
Moisture alone is bad enough, but combined with refrigerants containing chlorine, hydrochloric acids can form. These greatly increase the corrosion of metals.
Also, refrigerant oil rapidly absorbs moisture. Water-formed acids combine with the refrigerant, forming a closely bonded mixture of fine globules.
The effect is called sludging and it greatly reduces the lubricating ability of the oil.
A vacuum pump removes troublesome moisture by lowering the pressure within the system and vaporizing (or boiling off) the moisture, then exhausting it along with air.
Operation
It can continue work 10-14hours without stop. But please make sure sufficient oil.